Challenges of Electrical Energy Transport on Military Sites
The transport and distribution of electrical energy on military sites around the world represent a strategic issue, where reliability, discretion, and security are major imperatives.
Military facilities, often located in hostile or isolated environments, require power supplies capable of operating safely, ensuring constant availability, and withstanding extreme conditions—whether harsh climates, rugged terrain, or physical threats.
Underground Energy Distribution Solutions
The underground energy distribution solutions offered by AUGIER address these challenges by providing a discreet, robust, and reliable infrastructure. These systems make it possible, for example, to supply targets on firing ranges in an invisible and secure way. AUGIER solutions can also power lighting and intrusion-prevention equipment on security fences, reinforcing the protection of sensitive perimeters while reducing the visual footprint of installations. This discretion is essential to preserve the confidentiality of operations and limit vulnerabilities.
However, the challenges are not limited to discretion. Military sites often face peaks in energy consumption, particularly during intensive operations. Electrical networks must therefore be designed to withstand these fluctuations while maintaining flawless stability. AUGIER solutions enable networks to adapt effectively to such temporary demands.
AUGIER technology is used in all areas of electrical power supply for various loads such as:
- Lighting: functional, security, emergency, intervention
- CCTV camera system (simple, thermal, infrared)
- Intrusion detection, passage gates, surveillance booths
- Radar and radio systems for guiding aircrafts
- Articulated targets for ground fire tests
- Supplying basic living needs, remote power plants
PRODUCTS FOR Military Sites
IMPLEMENTED IN Military Sites
Discover our references around the world using AUGIER technologies.
Securing a military site
Installation of two step-up substations powered by two different low-voltage sources. Each step-up substation supplies watertight transformers installed in a pit from two on load switch.
Military shooting range
Creation of several three-phase 5500 V networks equipped with watertight transformers installed in pits, transformers powered by 3x16 mm² cables.
Safety enclosure power supply at an airport, U.A.E
Project features TOTAL POWER: 630 kVA TRANSPORT VOLTAGE: 5500 V NETWORK DISTANCE: 16 KM LOCATION: Fujairah, UAE YEAR: 2008 PROJECT OBJECTIVES Providing the electrical power supply for the lighting of the security perimeter walls at Fujairah Airport, UAE. Total...